FX302 FX503
SEPARATELY EXCITED (SX) TRANSISTORIZED MOTOR CONTROLLERS
FOR GOLF CART AND NEIGHBORHOOD ELECTRIC VEHICLE APPLICATIONS
- 300 and 500 amp controllers available for 36 and 48 volt applications
|
- 18-20 MPH with new replacement controller on most stock carts
|
- Units pre-programmed to particular cart and motor applications for optimal performance
|
- No setting changes or programming necessary, PLUG AND PLAY
|
- Great for Stock and Upgraded motors
|
- Part Numbers shown below include all adapter harnesses necessary
|
|
YAMAHA |
| Yamaha G19/G22 |
300A 48V Stock Motor |
300A 48V D-396/7 Motor |
|
500A 48V Stock Motor |
500A 48V D-396/7 Motor |
|
| FSIP P/N |
51-FX302G022 |
51-FX302G017 |
|
51-FX503G022 |
51-FX503G017 |
|
|
|
|
|
|
|
|
|
CLUB CAR |
| Club Car PDP Regen I & II |
300A 48V Stock Motor |
300A 48V D-391 Motor |
300A 48V D-388 Motor |
500A 48V Stock Motor |
500A 48V D-391 Motor |
500A 48V D-388 Motor |
FSIP P/N (I)
|
51-FX302G320K |
51-FX302G314K |
51-FX302G316K |
51-FX503G320K |
51-FX503G314K |
51-FX503G316K |
FSIP P/N (II)
|
51-FX302G020K |
51-FX302G014K |
51-FX302G016K |
51-FX503G020K |
51-FX503G014K |
51-FX503G016K |
|
|
|
|
|
|
|
| Club Car IQ |
300A 48V Stock Motor |
300A 48V D-390 Motor |
300A 48V D-388 Motor |
500A 48V Stock Motor |
500A 48V D-390 Motor |
500A 48V D-388 Motor |
| FSIP P/N |
51-FX302G021K |
51-FX302G015K |
51-FX302G016K1 |
51-FX503G021K |
51-FX503G015K |
51-FX503G016K1 |
|
|
|
|
|
|
|
|
E-Z-GO |
| E-Z-GO DCS |
300A 36V Stock Motor |
300A 36V EY7-4001 Motor |
300A 48V Stock Motor |
500A 36V Stock |
500A 36V XP-2140 Motor |
500A 48V Stock Motor |
| FSIP P/N |
51-FX302G023K |
51-FX302G018K |
51-FX302G025K |
51-FX503G023K |
51-FX503G018K |
51-FX503G025K |
| E-Z-GO PDS |
|
|
|
|
|
|
| FSIP P/N |
51-FX302G024K |
51-FX302G019K |
51-FX302G026K |
51-FX503G024K |
51-FX503G019K |
51-FX503G026K |
Click Here for installation instructionsNOTE: Max Current for FSIP Shunt controllers is approximately 50 amps above adjustable Current Limit Setting.
Specifications*
| Package dimensions: |
See Drawing link below |
| Voltage Range |
24-48 Volts DC |
| Maximum Available armature current….. |
300 & 500 amps (50% on time) |
| Maximum Available field current |
20 & 30 amps |
| Operating temperature |
-40oC to +50oC |
| Storage temperature |
-40oC to +85oC |
| Thermal Protection |
Non-Linear 90oC Cutback |
| Accelerator Input |
5k to 0 Ohms, 0 to 5k Ohms or 3 wire |
| Power Devices |
MOSFETS |
| Motor Reversing |
Solid State |
| Operating frequency (Armature): |
15 kHz |
| Operating frequency (Field) |
2.2kHz |
| Modulation |
PWM |
| Adjustment Method |
RS232 |
| On-board Coil Suppression |
Yes |
| Reverse Battery Protection |
Yes |
| Regenerative Braking |
Yes |
| Zero Speed Detection |
Yes |
| Reverse Buzzer Driver |
Yes |
| SRO |
Limited |
| Plugging (F to R) |
Yes |
| Reverse Speed Limit |
Adjustable |
| Operating Voltage |
Max 125% Nom. |
| Operating Voltage |
Min 50% Nom. |
Control Feature Descriptions
Regenerative Barking –
1. Control keeps vehicle from over speeding and regulates speed to value set by function 20 in Table 1 or the value set by table 2. This function is engaged when start switch is closed and speed reaches value set by function 20 or the value set by table 2.
2. Control slows vehicle down to approximately 10 MPH when start switch is opened.
Zero Speed Detection – Control prevents vehicle from rolling away once control see’s zero speed and no further inputs are received at the control. This function retarding torque is limited by max current allowed as set by function 5.
Reverse Buzzer Driver –
1. Turns customer supplied buzzer on when control see’s reverse signal.
2. Buzzer is also turned on and off when zero speed detect is initiated.
3. Buzzer current not to exceed 50mA.
SRO – Static Return to Off –
1. Vehicle will not run if the key is turned on with accelerator switch closed.
2. Vehicle speed is limited to Pedal up speed limit if the key is opened when the accelerator pedal is full on.
Plugging – Control provides retarding torque when a direction switch occurs. Retarding torque is limited by function 5 setting table 1
Reverse Speed Limit – Control limits motor volts to a valued specified by function 12, table 1, when control see’s reverse switch closed. Function 3, table 1, is doubled in reverse.
Reverse Battery Protection – If battery cables are hooked up backwards control will not allow line contactor to close.
Throttle wire Protection – Control will not run if +5v or wiper negative connection is open. 4V or greater at start switch closure.
Reverse Motor Protection – If (I) A and (I) F lead is switched control will not be damaged.
Stall Protection – If armature current is 145A or greater when speed is 1 MPH or less for 4 seconds, armature % on-time will be reduced by 8%. The timer is then reset to reactivate the stall protection feature.
FX-300 Current Limit

FX-500 Current Limit

FX-300 Arm I vs. Field I

FX-500 Arm I vs. Field I

Validation Testing
Thermal Shock – One control was soaked for one hour at -40oC then transitioned to 105oC within 5 seconds and soaked for 1 hour, to complete one cycle. Test preformed 100 cycles and control card operated properly after test.
Environmental Protection – TESTED TO IP53
Vibration – One control has been subjected to the Navy Manufacturing screening program (NAVMAT – P9492) vibration test. Random vibration from 20Hz to 2000Hz for 5 minutes in each plane (X,Y,Z). The Magnitude is 20 G rms. Control properly operated after test.
Shock – One control was subjected to 3 pulses of 20G in each of the 3 major axis. No physical damage occurred and control properly operated after test.
Power Cycle – One control was operated at full current rating (50% on time) for 10 seconds and off for 40 seconds. Control completed 100,000 cycles.
Table 1
GE Sentry
|
Function |
Description |
Setting |
|
1 |
MPH Scaling |
13 |
|
2 |
Creep Speed |
205 |
|
3 |
Controlled Acceleration |
15 |
|
4 |
Current Limit |
255 |
|
5 |
Plugging Current Limit |
255 |
|
6 |
Odometer Scaling |
85 |
|
7 |
Minimum Field Current |
78 |
|
8 |
Maximum Field Current |
130 |
|
9 |
Regen Armature Current Limit |
255 |
|
10 |
Regen Field Current Limit |
195 |
|
11 |
Not Applicable |
0 |
|
12 |
Reverse Speed Control |
100 |
|
13 |
Not Applicable |
0 |
|
14 |
Battery Compensation |
12 |
|
15 |
Battery volts |
48 |
|
16 |
Accel Select |
35 |
|
17 |
Not Applicable |
255 |
|
18 |
Field Gain 2 |
100 |
|
19 |
Field Gain 1 |
50 |
|
20 |
MPH Overspeed |
120 |
|
21 |
Field Ramp Pedal Up Regen |
2 |
|
22 |
Not Applicable |
0 |
|
23 |
Error Comp |
10 |
|
24 |
Field Weakening Start |
64 |
|
25 |
Not Applicable |
0 |
|
26 |
Ratio |
25 |
|
27 |
Minutes |
0 |
|
28 |
Fault Pointer |
0 |
|
29 |
HR 100 |
0 |
|
30 |
HR 1 |
0 |
|
|
|
|
|
117 |
Field Calibration |
128 |
|
118 |
Field Calibration |
128 |
|
119 |
Armature Calibration |
128 |
|
120 |
N/A |
128 |
|
121 |
Amphours 1 |
0 |
|
122 |
Amphours 100 |
0 |
|
123 |
Car Number |
0 |
|
124 |
Mode Select |
0 |
|
125 |
Miles 1 |
0 |
|
126 |
Miles 100 |
0 |
|
127 |
.1 Miles |
0 |
|
128 |
N/A |
0 |
Outline Drawing FX-300
Outline Drawing FX-500
Golf Car Application Input/Output List
Connections to Main Plug (23 Pin)
|
FX-300 CONTROLLER |
|
|
FX-500 CONTROLLER |
|
|
PIN |
MAIN PLUG INPUT/OUTPUT DESCRIPTION |
|
PIN |
MAIN PLUG INPUT/OUTPUT DESCRIPTION |
|
1 |
BATTERY VOLTS FROM TOW SWITCH |
|
1 |
BATTERY VOLTS FROM TOW SWITCH |
|
2 |
BATTERY VOLTS FROM TOW SWITCH |
|
2 |
BATTERY VOLTS FROM TOW SWITCH |
|
3 |
BATTERY VOLTS FROM ACCELERATOR START SWITCH |
|
3 |
BATTERY VOLTS FROM ACCELERATOR START SWITCH |
|
4 |
BATTERY VOLTS FROM FORWARD SWITCH |
|
4 |
BATTERY VOLTS FROM FORWARD SWITCH |
|
5 |
BATTERY VOLTS FROM REVERSE SWITCH |
|
5 |
BATTERY VOLTS FROM REVERSE SWITCH |
|
6 |
BATTERY VOLTS FROM KEY SWITCH |
|
6 |
BATTERY VOLTS FROM KEY SWITCH |
|
7 |
ACCELERATOR INPUT VOLTAGE SIGNAL |
|
7 |
ACCELERATOR INPUT VOLTAGE SIGNAL |
|
8 |
ACCELERATOR NEGATIVE |
|